www.enersys.com
Technical Data Sheet
Add water just four
to six times per year
vs. every week
With 90,100 and 125 amp-hour plates, Deserthog® batteries hold up to 132% more water
than standard batteries, reducing watering intervals for a more efficient operation with lower
maintenance costs.
No. of Plates
Cell
Catalog #
Capacity @ 6 hr. Rate @ 77°F or
5 hr. Rate @ 30°C to 1.70 Vpc
Base Dimensions of Cells*
Weight of Electrolyte
Approx. Weight Per Cell**
Length
Width
kWh
AH
in
mm
in
mm
lbs
kg
lbs
kg
325340-CW
0.35
180
2.00
51
6.19
157
6.4
2.9
33
15.0
325341-CW
0.52
270
2.75
70
6.19
157
8.6
3.9
47
21.3
325342-CW
0.69
360
3.50
89
6.19
157
10.7
4.9
57
25.9
11
325343-CW
0.87
450
4.25
108
6.19
157
12.8
5.8
70
31.8
13
325344-CW
1.04
540
5.00
127
6.19
157
14.9
6.8
82
37.2
15
325345-CW
1.22
630
5.75
146
6.25
159
18.2
8.3
94
42.6
17
325346-CW
1.39
720
6.50
165
6.25
159
20.3
9.2
107
48.5
19
325347-CW
1.56
810
7.25
184
6.25
159
22.3
10.1
119
54.0
21
325348-CW
1.74
900
8.00
203
6.25
159
24.6
11.2
132
59.9
23
325349-CW
1.91
990
8.75
222
6.25
159
27.7
12.6
145
65.8
25
325350-CW
2.08
1080
9.50
241
6.25
159
29.9
13.6
158
71.7
27
325351-CW
2.26
1170
10.25
260
6.25
159
32.0
14.5
170
77.1
29
325352-CW
2.43
1260
11.00
279
6.25
159
35.2
16.0
184
83.5
31
325353-CW
2.61
1350
11.75
298
6.25
159
37.3
16.9
194
88.0
33
325354-CW
2.78
1440
12.50
318
6.25
159
39.5
17.9
205
93.0
E90D - Square Tubular (90 AH per Positive Plate)
Standard coverless battery height is 22.81”over lifting ear
* Tray, tray partitions and required clearance make complete batteries up to 1.00” longer and wider than cells alone
** Including steel tray
4-6x
per year
LESS WATERING
Industry-leading amp-hour
capacity rating
AMP HOURS
Extended run times
allow trucks to last
longer into the shift
RUN TIMES
Up to 5-year +1 warranty
depending on charging
applications
YEAR
LIMITED
WARRANTY